The investigation by Wada et al published in the Journal compared standard CPR, precordial percussion pacing (PPP) and electrical pacing in microminipigs and has provided important new mechanistic insights as it showed the probable importance of stretch-activated ion channels.1 With reference to their study, we would like to present a video of PPP which, to the best of our knowledge, shows for the first time in the human cardiac output (CO) measurement during percussion pacing. We can demonstrate that it was able to generate a normal CO. PPP (i.e., repetitive taps to the chest) has potential to function as a manual transcutaneous pacemaker. Even though the technique is mentioned briefly in the guidelines of the European Resuscitation Council,2 it is seldom used in clinical practice. A 76-year old man developed bradyasystole after resection of a renal tumor that extended into the inferior caval vein. Luckily, the patient was under continuous hemodynamic monitoring using a PiCCO-device, permitting us to measure CO during the event. As bradyasystole occurred, most likely caused by third-degree atrioventricular block (AVB), circulation stopped immediately as indicated by the flat lines on the tracings of pulse oximetry (SpO2) and invasive blood pressure (IBP). While waiting for an external pacemaker, one physician commenced to knock on the chest with one fist at a frequency of approximately 90 beats/min and with a force far less than required for chest compressions as in cardiopulmonary resuscitation (CPR) (Figure A, Movie S1). Each beat was followed by a ventricular complex on ECG and amplitudes on IBP and SpO2 of usual appearance. This tapping of the chest was interrupted four times. Each time ECG, IBP and SpO2 tracings went flat and returned after resumption of the taps. BP generated by this manual pacing was 140/60 mmHg, and a cardiac index of 3.0 L/min/m2 was measured by PiCCO (Figure B, Movie S1). Pacing was continued electrically, first via a transcutaneous, later a transvenous pacemaker. Despite initially successful resuscitation, the patient died 3 days later from persistent SIRS and multi-organ failure.
(A) Tapping of the chest to generate ventricular contractions. (B) Monitor showing normal arterial pressure and cardiac output.
This is, to the best of our knowledge, the first reported case of percussion pacing on video and the first documentation of PPP, including online BP and CO measurement in a human. It demonstrates that PPP, which is based on the conversion of mechanical to electrical energy,3 can stimulate ventricular contractions sufficient to generate normal BP and CO. Case series have reported its successful application for asystole or total AVB in both adult and pediatric patient populations.3 However, case reports or human studies directly measuring CO achieved by PPP have not been available. Chan et al extrapolated a presumed CO of 3.3 L/min generated by PPP, based on measurements from a pulmonary artery catheter inserted after stabilization of the patient.4 In dogs, percussion pacing restored a virtually normal CO and was much more effective than chest compressions in a study from 1987.5 Our video illustrates that PPP might be worth a try in case of unstable bradycardia or bradyasystole as a potential “bridge to pacemaker” to ensure sufficient CO. As animal studies have shown a higher efficiency compared with CPR,1,5 PPP might be preferable to CPR and the treatment approach of choice if monitoring of its efficiency, such as ECG, IBP measurement or reliable pulse palpation, is available. We deem it prudent, however, to perform PPP only when its efficiency can be monitored and to perform conventional CPR in other circumstances.
None.
Supplementary File 1
Movie S1. Video of percussion pacing. ECG, IBP and SpO2 on the large monitor in the upper left corner, cardiac output on the small PiCCO monitor in the lower left corner.
Please find supplementary file(s);
http://dx.doi.org/10.1253/circj.CJ-17-0783