Circulation Journal
Online ISSN : 1347-4820
Print ISSN : 1346-9843
ISSN-L : 1346-9843
Images in Cardiovascular Medicine
Avulsion of Previously Implanted Stent by Directional Coronary Atherectomy ― Intravascular Ultrasound and Angioscopic Evaluation ―
Yasuyuki EgamiRyu ShuttaKohei UkitaAkito KawamuraHitoshi NakamuraYutaka MatsuhiroKoji YasumotoMasaki TsudaNaotaka OkamotoAkihiro TanakaYasuharu Matsunaga-LeeMasamichi YanoMasami NishinoJun Tanouchi
Author information
JOURNAL OPEN ACCESS FULL-TEXT HTML
Supplementary material

2020 Volume 84 Issue 12 Pages 2321-

Details

We present a case of a 64-year-old man with severe in-stent restenosis of a bare metal stent (4.0×15 mm) in the left anterior descending (LAD) (Figure A). Because the coronary angiogram suggested massive neointimal hyperplasia in the stent, we chose to use a debulking device to reduce the in-stent tissue and gain sufficient lumen area. Intravascular ultrasound (IVUS) showed diffuse intimal hyperplasia and no stent malapposition (Figure A-a–d). Directional coronary atherectomy (DCA) was performed at 20 psi to the distal section of the stent, followed by the proximal section. There was an abnormal sound after the last attempt at DCA and the device was entrapped within the stent. Careful retrieval revealed a metal mass wrapped around the housing of the device (Figure B). Subsequent coronary angiography showed a filling defect in the mid-LAD (Figure C). To evaluate the vessel’s condition, both IVUS and coronary angioscopy were performed and revealed no stent structure; angioscopy showed mobile, peeled intima but no thrombi (Figure D,E; Supplementary Movies 1,2). We implanted a new bare metal stent.

Figure.

(A) Coronary angiography and intravascular ultrasound before DCA. The dashed lines indicate the contour of the previously implanted stent. (a) Proximal site, (b) middle site and (c) distal site of in-stent restenosis. (d) Distal edge of stent. (B) (Upper) Retrieved DCA catheter and metallic mass with white tissue (black arrowheads). Black arrow indicates the direction of the tip of the DCA catheter. (Lower) Retrieved stent with white tissue. (C) Coronary angiogram showing filling defect in the LAD (white arrowhead). (D) Intravascular ultrasound showed the protruding plaque (white arrows). (E) Angioscopy showing peeled intima (black arrow). DCA, directional coronary atherectomy; LAD, left anterior descending coronary artery.

It is very rare that a stent will be avulsed by a coronary intervention.1 Attention should be paid to stent avulsion when performing DCA for in-stent restenosis.

Funding / Disclosures

None.

Supplementary Files

Supplementary Movie 1. IVUS image after DCA.

Supplementary Movie 2. Coronary angioscopic image after DCA.

Please find supplementary file(s);

http://dx.doi.org/10.1253/circj.CJ-20-0610

Reference
  • 1.   Matsuhiro Y, Shutta R, Egami Y, Nishino M, Tanouchi J. Orbital atherectomy through left main stent struts complicated by catheter entrapment and stent avulsion. JACC Case Rep 2020; 2: 709–710.
 
© 2020 THE JAPANESE CIRCULATION SOCIETY

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
feedback
Top