Circulation Journal
Online ISSN : 1347-4820
Print ISSN : 1346-9843
ISSN-L : 1346-9843

This article has now been updated. Please use the final version.

Anticoagulation Therapy After Left Ventricular Assist Device Implantation
Yoshihisa TanoueTakeo FujinoAkira Shiose
Author information
JOURNAL FREE ACCESS FULL-TEXT HTML Advance online publication

Article ID: CJ-18-0329

Details

The implantable left ventricular assist device (LVAD) for the treatment of advanced heart failure has played a substantial role as a bridge-to-transplant procedure, and as long-term support for non-transplant candidates (i.e., destination therapy).1 Although a LVAD improves survival and the quality of life for patients with advanced heart failure, the benefits are limited, with a defined risk of adverse events, such as pump thrombosis, bleeding, infection, aortic regurgitation, and right-sided heart failure.2 These LVAD-related complications indicate the limitations of current treatment. In particular, thromboembolic and bleeding events are major complications following LVAD implantation. The current anticoagulation therapy used in patients with a LVAD is administration of a vitamin K antagonist (warfarin) in combination with antiplatelet therapy.3 Tight control of the prothrombin time-international normalized ratio is considered crucial for the reduction of postimplant thromboembolic and bleeding complications. Firm and secure protocols are necessary for standardization of treatment, and for improvements in patient care. However, the dilemma of under- or over-anticoagulation arises, and there will always be a need for clinical judgement based on the experience of individual facilities and institutional preferences.

Article p ????

HeartMate II (HM2; Abbott Laboratories, Chicago, IL, USA) is a small, 2nd-generation, continuous, axial-flow type pump,4 and is currently the most commonly implanted durable LVAD in many countries around the world.1 The clinical experience and knowledge backed up by many studies on the HM2 contribute to the excellent outcomes.5,6 Safe long-term support using HM2 has also been achieved by improvements in medical management, and reductions in complication rates.1,2,46 Pump thrombosis after HM2 implantation is one of the most extensively discussed problems.710 Anticoagulation therapy is a major factor preventing pump thrombosis, whereas too strict anticoagulation regimens increase the risk of bleeding complications. Individualized management in accordance with the conditions of each patient and the HM2 implantation is critically important. The recommendations for adequate anticoagulation therapy, even after the implantation of a HM2, are still ambiguous in clinical reality.

In this issue of the Journal, Zayat et al11 report 13 patients who underwent HM2 implantation without anticoagulation therapy because of recurrent bleeding complications. All patients had impaired platelet function and acquired von Willebrand syndrome.11 No pump thrombi occurred, and there was only 1 case of ischemic stroke.11 Although all cases had definitive reasons to abort anticoagulant therapy, the clinical results were rather good.11 These results suggest that the coagulation disorder caused by HM2 implantation paradoxically resulted in improvement in the thrombosis/bleeding spectrum after cessation of anticoagulation therapy. Acquired coagulopathy, platelet dysfunction, and impaired von Willebrand factor activity in LVAD patients has yet to be clearly established.12,13 Zayat et al11 show that their 13 HM2 patients who did not receive a vitamin K antagonist seemed to have a balance between bleeding risk (low von Willebrand factor ratio) and thromboembolic risk (high thrombin-antithrombin III complex value). They suggest that some patients can tolerate cessation of anticoagulation therapy without a resultant increase in the thromboembolic rate.11 This means that some patients implanted with HM2 who have a low von Willebrand factor ratio and high thrombin-antithrombin III complex value would not necessarily need anticoagulant therapy, even those without bleeding complications. A more complete understanding of the influence of a LVAD on the coagulation pathway and the fibrinolytic system is necessary to reduce complications, improve survival times, and enable LVAD implantation to become a true long-term alternative to heart transplantation.

References
 
© 2018 THE JAPANESE CIRCULATION SOCIETY