靜脈還流に關する臨床的並に實驗的研究(第2報) : 第2報 人工氣胸の靜脈還流に及ぼす影響に就いて(頸靜脈波,左心房曲線 人)
高嶋 學
著者情報
ジャーナル フリー

1953 年 17 巻 8 号 p. 376-381

詳細
抄録
The author investigated the change of venous wave or auricular wave before and after artificial Pneumothoraces in patients of pulmonary tuberculosis or in dogs, and obtained following results. (1) Depth of X-valley in venous wave decreased after Pneumothorax and increased after discharge of air from pleural cavity. This was also the case in S_m-wave of auricular wave. (2) When large amount of air was introduced continuously or cumulatively, depth of S_m-wave decreased not in linear but in parabolical relation to the amount of air introduced. (3) Both before and after Pneumothorax, when preceding cardiac cycle was long, S_m-wave or X-valley denotes the suction-power of heart (s. 1st report), these experimental results show that suction-mechanism of heart is closely related to pulmonary suction-mechanism.