2021 年 10 巻 11 号 p. 881-886
We have fabricated a transverse electromagnetic (TEM) horn for radiated immunity tests in close proximity as specified in standard IEC 61000-4-39 and compared its near-field characteristics with those of other typical test antennas such as broadband dipole and double-ridged guide (DRG) horn antennas. Experimental results show that the TEM horn generates a homogeneous field and maintains the field strength without a rapid change near the antenna.