Twenty-four Hour Flexural and Shear Bond Strengths of Flowable Light-cured Composites: A comparison Analysis Using Weibull Statistics
Rosalina TJANDRAWINATAMasao IRIEKazuomi SUZUKI
著者情報
ジャーナル フリー

2007 年 26 巻 4 号 p. 589-597

詳細
抄録
By means of Weibull analysis, this study evaluated and compared the flexural strength and shear bond strength of flowable light-cured composites against those of conventional ones. Twenty specimens of each material were prepared for flexural and shear bond strength measurements. Specimens were measured after water storage at 37°C for 24 hours. Three of four flowable composites showed significantly higher flexural strength than conventional ones, with Weibull moduli ranging between 6 and 14. With the presence of a bonding agent, the shear bond strength to enamel of both types was not different significantly (p=0.28), with Weibull moduli ranging between 4 and 9. In the selection of an excellent resin composite material, results of this study showed that a high, stable Weibull modulus value could be a sound indicator.
著者関連情報
© 2007 The Japanese Society for Dental Materials and Devices
前の記事 次の記事