繊維学会誌
Online ISSN : 1884-2259
Print ISSN : 0037-9875
一般報文
平板状熱源に挟まれた布における熱伝導
真壁 文子高久  明
著者情報
ジャーナル フリー

2005 年 61 巻 2 号 p. 38-42

詳細
抄録
The thermal resistance of ordinary textile fabrics is so small that in the measurements of thermal conduction by sandwiching a specimen between two planar heat sources, the contact resistance of the specimen to the surfaces of heat sources becomes relatively larger than the thermal resistance of the specimen itself. In order to analyze the heat flow in this situation, a model taking into account the contact resistance for reducing the thermal conductivity as a parameter independent of fabric thickness was proposed. The changes of heat flow rate with thickness for layered specimens composed of the same fabric were measured for a series of woven and knitted fabrics. The contact resistance of the fabrics used was about 1.31 m2 K/kW in average. The thermal conductivity calculated by the model showed a tendency decreasing with increasing porosity. The heat flow rate of layered specimens composed of different kind fabrics, which was calculated by the model from the contact resistance and the thermal conductivity of component fabrics, was in good agreement with measured values. The apparent thermal conductivity calculated by assuming the temperature difference between the specimen surfaces being the same with that between the heat sources showed an increasing tendency with increasing thickness.
著者関連情報
© 2005 The Society of Fiber Science and Technology, Japan
前の記事 次の記事
feedback
Top