Abstract
Neutralization behavior and anti-mold performance of plaster coating materials were evaluated through an accelerated carbonation test and the mold resistance test based on JIS Z 2911. It was found that neutralization depth of plaster coating materials did not follow the parabolic law. It was also recognized that plaster coated layers showed anti-mold performance to some extent even after carbonation.