Summaries of Technical Papers of Annual Meeting Japan Society for Finishings Technology
Online ISSN : 2760-3423
Summaries of Technical Papers of Annual Meeting 2018
Conference information

Summaries of Technical Papers of Annual Meeting 2018
Fire resistance tests of specific door assemblies protected with with calcium silicate board
*Jun-ichi SUZUKITomohiro NARUSETensei MIZUKAMIKatsuo OGUNI
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Pages 125-128

Details
Abstract

Building elements such as columns, beams, walls and floors are ordinarily protected with fire protection material to assure the sufficient fire resistance of the building elements exposed to fire. Load bearing capacity and insulation and/or integrity of the building elements are required to prevent a building from collapse and fire spread in a fire. Autoclaved light-weight concrete panel (ALC panel) is a fire protection material and widely used. In this study, fire resistance tests were conducted to clarify the temperature characteristics of protected emelents.

Content from these authors
© 2018 Japan Society for Finishings Technology

この記事はクリエイティブ・コモンズ [表示 - 非営利 - 改変禁止 4.0 国際]ライセンスの下に提供されています。
https://creativecommons.org/licenses/by-nc-nd/4.0/deed.ja