水素エネルギーシステム
Online ISSN : 2436-5599
Print ISSN : 1341-6995
特集 「グリーン水素の大量導入に向けて」
大型アルカリ水電解水素製造技術に関する雑考
真鍋 明義錦 善則
著者情報
研究報告書・技術報告書 フリー

2021 年 46 巻 3 号 p. 172-178

詳細
抄録

This paper mentions activated anodes and gas effects on electrodes in electrolyte, current distribution, leakage current resulting from the electrolytic process, gas purity, and safety of the process during water electrolysis, which have a large impact on plant performance, with regard to the actual alkaline water electrolysis technology. When the plant operation is faced with day and night intermittent operation, the degradation of anode coating is remarkable. Although the safety is top issues in actual plant operation, unlike common sense images, the most dangerous condition is when driving a plant at a low load. It should be understood that low-energy operation is the most dangerous condition because it is easy to reach the explosion limit of hydrogen gas.

著者関連情報
© 2021 一般社団法人 水素エネルギー協会
前の記事 次の記事
feedback
Top