電気学会論文誌A(基礎・材料・共通部門誌)
Online ISSN : 1347-5533
Print ISSN : 0385-4205
ISSN-L : 0385-4205
論文
メタルハライドランプにおけるバイパス回路付漏れ変圧器形点灯回路の研究
三宅 秀信西嶋 清一郎家村 道雄
著者情報
ジャーナル フリー

2004 年 124 巻 11 号 p. 993-1001

詳細
抄録
A bypass circuit is set up in the secondary winding of ballast for the leakage transformer type operating circuit for a metal halide lamp.
It is shown from computer simulation and experiment that harmonic element containing rate of the power supply current wave form of the operating circuit can be controlled to be small by deciding optimal tap position of the bypass circuit and optimal values of circuit constants of the bypass circuit.
It is shown from experiment that the power factor of power supply current is about 100% by setting up a capacitor for the power factor improvement in the arrangement at the input terminal of the operating circuit.
著者関連情報
© 電気学会 2004
前の記事 次の記事
feedback