IEEJ Transactions on Fundamentals and Materials
Online ISSN : 1347-5533
Print ISSN : 0385-4205
ISSN-L : 0385-4205
Paper
Digitally Recorded Impulse Voltage Waveform and its Parameters
Shuji SatoHironori IchikawaTatsunori SaitouTatsuya HaradaMasahiro Hanai
Author information
JOURNAL FREE ACCESS

2006 Volume 126 Issue 12 Pages 1231-1237

Details
Abstract
Whereas high resolution digital recorders are used in recording the impulse voltage tests in prominent accreditation laboratories worldwide, a usage of an 8 bit recorder is also allowed by IEC publication. An 8 bit recorder is, due to its nature, known to record a waveform with 0.4% vertical resolution and it has not been appreciated for determining a peak value of lightning impulse in the reference measuring system where the scale factor is often evaluated with 0.1% or less uncertainty. This paper demonstrates simulation in which an 8 bit record with an internal noise is fed into the lightning impulse parameter determination software and the computed parameters were compared with theoretical values. The results show that, if suitable software is used, errors in parameters deduced from an 8 bit record is as small as those derived from a 12 bit record, suggesting an inexpensive 8 bit recorder can replace a 12 bit in impulse voltage measurements.
Content from these authors
© 2006 by the Institute of Electrical Engineers of Japan
Previous article Next article
feedback
Top