Partial Discharge Inception Characteristics and V-t Characteristics of Sheath Material of Cables for High Voltage Inverter Systems
Kotaro WadaKosei TsujiHirotaka MutoShoji Mizoguchi
Author information
JOURNAL FREE ACCESS

2007 Volume 127 Issue 2 Pages 71-77

Details
Abstract

In inverter drive systems, surge voltage between cable shield and ground (generally 0V in AC drive systems) caused from inverter switching is induced if cable length is longer and dv/dt of the inverter output voltage is much higher. This surge voltage isn't observed under AC drives. This unexpected surge voltage may cause partial discharge at cable sheaths and finally breakdown if the surge voltage exceeds partial discharge inception voltage (PDIV) of the sheaths. Therefore insulating characteristics of cable sheaths under inverter surge should be understood for optimal design of inverter-motor systems. This report states about insulating characteristics of the cable sheath, especially PDIV and V-t characteristics under AC and high dv/dt pulse voltage.