電気学会論文誌A(基礎・材料・共通部門誌)
Online ISSN : 1347-5533
Print ISSN : 0385-4205
ISSN-L : 0385-4205
特集論文
ESDガンのIEC較正用電流検出変換器に対する伝達インピーダンスの測定と検証
山中 幸雄足立 貴士石上 忍森 育子高 義礼藤原 修
著者情報
ジャーナル フリー

2012 年 132 巻 5 号 p. 350-355

詳細
抄録
In the present study, using a 50Ω tapered coaxial type adapter and a S-parameter technique, we measured the transfer impedance of a commercially available IEC calibration current target used for the immunity testing against electrostatic discharges (ESDs), which is being prescribed in the International Electrotechnical Commission (IEC) 61000-4-2, and thereby reconstructed the waveforms of discharge currents injected onto the target from their observed output voltages for contact and air discharges of an ESD generator. As a result, we found that the transfer impedance is almost 1+j0Ω at frequencies below 1GHz, while due to resonance phenomena occurring at frequencies around 2GHz and 5GHz, resistive and reactive components significantly change at frequencies over 1GHz, though their absolute values are slightly larger than 1Ω. This result has revealed that the reconstructed discharge currents agree well with the observed voltages with a rise time of almost 1ns for the contact discharges and air discharges with slow approach of an ESD gun with charge voltages above 2kV, while in the case for the observed voltage with a rapid rise time shorter than a hundred pico-seconds for the air discharges with fast approach, the reconstructed discharge current has a bit gentle rising slope and a slightly lower level of the first current peak.
著者関連情報
© 電気学会 2012
前の記事 次の記事
feedback
Top