電気学会論文誌A(基礎・材料・共通部門誌)
Online ISSN : 1347-5533
Print ISSN : 0385-4205
ISSN-L : 0385-4205
特集論文
繰り返しインパルス印加時のモータコイルにおける電界緩和層の電位分布および温度分布
中村 隆央熊田 亜紀子池田 久利日髙 邦彦Steven A. Boggs坪井 雄一木崎原 智仁櫻井 孝幸吉満 哲夫
著者情報
ジャーナル フリー

2015 年 135 巻 2 号 p. 100-106

詳細
抄録
Recently, it has been pointed out that the erosion of stress grading systems of converter-fed rotating machines may occur by partial discharges and heat generation. It is necessary to measure not only temperature distributions but also potential distributions to grasp the erosion process and to design reliable insulation systems even under inverter surges. Therefore, in this study, the potential distributions under repetitive pulses were measured by a Pockels sensor which covers wide frequency up to GHz. Consequently, it was observed that the field concentrates on the Corona Armor Tape (CAT) closer to the stator core under shorter rising impulse voltage. In addition to this, it has been confirmed that the field concentrates on the CAT during the wave-front of impulses and on Stress Grading Tape (SGT) in the wave-tail of impulses.
著者関連情報
© 2015 電気学会
前の記事 次の記事
feedback
Top