IEEJ Transactions on Fundamentals and Materials
Online ISSN : 1347-5533
Print ISSN : 0385-4205
ISSN-L : 0385-4205
Special Issue Paper
Partial Discharge Inception Voltage and Location of Partial Discharge Source in Ribbon Type Enameled Wire
Hirotaka NakayaMasahiro KozakoMasayuki HikitaKeiichi TomizawaMakoto OyaDaisuke Muto
Author information
JOURNAL FREE ACCESS

2015 Volume 135 Issue 2 Pages 107-112

Details
Abstract
As technology of inverter-fed motors progresses in recent years, means of protection against inverter surge for the motor windings have been developed. It is strongly required for windings used in electric vehicles and hybrid electric vehicles to have excellent insulations properties together with high heat resistance, especially high partial discharge inception voltage (PDIV). This paper deals with PDIV of ribbon-type enameled wire which is fabricated to increase space factor in the motor windings compared with the conventional enamel wire.
Content from these authors
© 2015 by the Institute of Electrical Engineers of Japan
Previous article Next article
feedback