電気学会論文誌A(基礎・材料・共通部門誌)
Online ISSN : 1347-5533
Print ISSN : 0385-4205
ISSN-L : 0385-4205
特集論文
遮熱コーティングの界面酸化層検出におけるトップコート透過率測定と感度評価
福地 哲生江藤 修三岡田 満利藤井 智晴
著者情報
ジャーナル フリー

2015 年 135 巻 4 号 p. 191-197

詳細
抄録
The thermally grown oxide (TGO) layer, which forms below the topcoat of thermal barrier coating (TBC), is an important factor which causes topcoat delamination, and its detection is important for health monitoring of TBC. Photoluminescence detects the emission from Cr3+ in the TGO layer upon laser excitation, and is an effective, nondestructive method to detect the TGO layer. In this method, the laser light and Cr3+ photoluminescence must transmit through the topcoat, so the topcoat transmittance is a limiting factor of the measurement sensitivity. In this report, the topcoat transmittance was measured by comparing the photoluminescence intensities from the TGO layer in the presence and absence of the topcoat. The round-trip transmittance of the topcoat of thickness 300 µm was 1.26 %, corresponding to an attenuation coefficient of 7.3 mm-1. The sensitivity of the luminescence measurement was evaluated by placing ND filters of known attenuation in front of the TGO layer, to simulate attenuation for different topcoat thickness. The results showed that luminescence measurement is possible for a maximum topcoat thickness of about 700 µm. A method to adjust the photoluminescence intensity for different topcoat thickness is presented.
著者関連情報
© 2015 電気学会
次の記事
feedback
Top