The air discharge currents from an ESD generator were measured at charging voltages from 2 kV to 15 kV in an environment with different temperature and humidity. Dependence of the current peaks on breakdown potential gradients in addition to spark lengths is shown, and is calculated using a simplified equivalent circuit based on the IEC standard for the ESD generator.