2022 Volume 142 Issue 3 Pages 122-123
An alternative testing method applicable to both air discharge and contact discharge is proposed via a fixed gap from an ESD generator in its contact discharge mode under conditions limited to a test voltage of 8 kV. The method can be used not only to provide the air discharge current close to the step response of the ESD generator through a fixed gap from 0.03 mm to 0.5 mm, but also via 1 mm gap to give the contact discharge current that meets IEC calibration requirements.
The transactions of the Institute of Electrical Engineers of Japan.A
The Journal of the Institute of Electrical Engineers of Japan