電気学会論文誌A(基礎・材料・共通部門誌)
Online ISSN : 1347-5533
Print ISSN : 0385-4205
ISSN-L : 0385-4205
模擬トリーからの摩耗的トリー伸展開始についての検討
今井 國治
著者情報
ジャーナル フリー

2001 年 121 巻 8 号 p. 803-804

詳細
抄録
In this paper, I have investigated relationship between partial discharge (PD) in a simulated tree channel and tree growth of fatigue failure type from its tip at temperature range from 20°C to 70°C. Voltage dependence of total number of PD pulses in voltage range where shape-parameter m in Weibull distribution was m_??_1 was obtained. Relationship between total number of PD pulse n and applied voltage V is represented by n∝V for each temperature. The exponents α do not change with temperature rise. Ahrrenus plot of total number of PD pulses allows to estimate activated energy to be 4.7kcal/mol. This value is less than chemical bonding energy of polymer chain such as C-C and C-H bonds, but is in good accord with physical one such as van der Waals force between CH3 bonds.
著者関連情報
© 電気学会
前の記事 次の記事
feedback
Top