IEEJ Transactions on Industry Applications
Online ISSN : 1348-8163
Print ISSN : 0913-6339
ISSN-L : 0913-6339
Special Issue Paper
Investigation for the Flashover Phenomenon in DC Machines
—Sastainable Voltage of DC Arc—
Yuji NakanishiKensho SugimotoNoboru Morita
Author information
JOURNAL FREE ACCESS

2009 Volume 129 Issue 11 Pages 1054-1059

Details
Abstract
Although in recent years, large DC machines have gradually been replaced with variable-speed AC machines, many large DC machines are still operating in steel mills. Flashover is still a frequent occurrence and has been ongoing issues since DC machines were first brought into use. In this investigation, flashover experiments were performed using model tests. The sustained voltage of the DC arc was cleared and copper dragging was found to be related to flashover.
Content from these authors
© 2009 by the Institute of Electrical Engineers of Japan
Previous article Next article
feedback
Top