電気学会論文誌D(産業応用部門誌)
Online ISSN : 1348-8163
Print ISSN : 0913-6339
ISSN-L : 0913-6339
論文
変換器容量の低減を目的とした電気鉄道用パワーラインコンディショナの制御法
石倉 規雄平木 英治田中 俊彦
著者情報
ジャーナル フリー

2009 年 129 巻 9 号 p. 907-913

詳細
抄録
This paper proposes a new control method for reducing the capacity of an active power quality compensator with a three-leg inverter used in electrified railways. In the proposed control method, the fundamental reactive and unbalanced-active components of the load currents are detected. The non-active and unbalanced-active components are compensated on the source side with the fundamental reactive power control. This reactive power control reduces the capacity of the three-leg inverter, which performs the active power quality compensator. The basic principle of the proposed control method is discussed in detail, and then confirmed by digital computer simulation using the PSIM software. A reduced-scale experimental model is constructed and tested. Experimental results demonstrate that the balanced sinusoidal source currents with the power factor of 0.9 are obtained, reducing the capacity of the three-leg inverter by 13% as compared to the already proposed control method.
著者関連情報