Comparison of Transformer Winding Methods for Contactless Power Transfer Systems of Electric Vehicle
Yasuyoshi KanekoNatsuki EharaTakuya IwataShigeru AbeTomio YasudaKazuhiko Ida
Author information
JOURNAL FREE ACCESS

2010 Volume 130 Issue 6 Pages 734-741

Details
Abstract
This paper describes the comparison of the characteristics of double- and single-sided windings of contactless power transfer systems used in electric vehicles. The self-inductance changes with the electric current when the gap length is fixed in single-sided windings. The issue is resolved by maintaining the secondary voltage constant. In the case of double-sided windings, the transformer can be miniaturized in comparison with the single-sided winding transformer. However, the coupling factor is small, and appropriate countermeasures must be adopted to reduce the back leakage flux. The leakage flux is reduced by placing an aluminum board behind the transformer. Thus, the coupling factor increases.