IEEJ Transactions on Industry Applications
Online ISSN : 1348-8163
Print ISSN : 0913-6339
ISSN-L : 0913-6339
Paper
A Carrier-Phase Control Suitable for Conducted EMI Noise Reduction in a Multiple-Converter System
Michio TamateAkio TobaYasushi MatsumotoKeiji WadaToshihisa Shimizu
Author information
JOURNAL FREE ACCESS

2011 Volume 131 Issue 6 Pages 811-819

Details
Abstract
Conducted EMI noise flowing from the power converters to AC utility line is regulated by international commissions such as International Electrotechnical Commission (IEC). For adherence to the IEC regulations, EMI filters should be used in power electronics equipment.
This paper proposes a method for analyzing the conducted EMI noise in multiple power converters connected to the same power line. In this method, the phase difference between sub-harmonic modulated carrier signals at each power converter is taken into account. The phase difference among the power converters determines the EMI noise level in a multiple-converter system, as is evident from the analysis of the waveform of the common-mode current. In addition, EMI noise suppression using a carrier-phase control is a proposed. In order to reduce volume of the EMI filter effectively, the phase difference θ should be set to 360/nN°; here, n is a high-order harmonic component at around 150kHz, and N is the number of power converters. Therefore, the conducted EMI noise can be reduced effectively with the help of the proposed phase control.
Content from these authors
© 2011 by the Institute of Electrical Engineers of Japan
Previous article Next article