IEEJ Transactions on Industry Applications
Online ISSN : 1348-8163
Print ISSN : 0913-6339
ISSN-L : 0913-6339
Paper
Loss Minimization Design Using Permeance Method for Interior Permanent Magnet Synchronous Motor
Daisuke SatoJun-ichi Itoh
Author information
JOURNAL FREE ACCESS

2015 Volume 135 Issue 2 Pages 138-146

Details
Abstract
In this study, the lowest loss point is calculated using the permeance method when the machine parameters of the interior permanent magnet synchronous motor are changed. Using the proposed method, the motor loss is easily calculated compared to the conventional method. The periodic change in the magnetic resistance in the air gap according to the rotation of the rotor does not need to be considered because the magnetic equivalent circuits of the rotor and stator are separated. In this study, the motor loss is calculated by the proposed method and a finite element method (FEM). As a result, the error in the calculation results between the permeance method and the FEM is 2.9%. On the other hand, the motor losses are calculated by the permeance method when some machine parameters are changed. As a result, these results agree in principle with those of the FEM. Therefore, the validity of the proposed method is confirmed. In addition, the method for motor design is considered in terms of the loss.
Content from these authors
© 2015 by the Institute of Electrical Engineers of Japan
Previous article Next article