IEEJ Transactions on Industry Applications
Online ISSN : 1348-8163
Print ISSN : 0913-6339
ISSN-L : 0913-6339
Paper
Quality Improvement of X-ray CT Images by Estimation of the Mechanical Misalignment in a Projection Image Using an Iterative Method
Kenji NoguchiSatoshi TakahashiDaisuke SuzukiAtsushi Teramoto
Author information
JOURNAL FREE ACCESS

2017 Volume 137 Issue 3 Pages 213-219

Details
Abstract

An X-ray computed tomography (CT) apparatus is required for the inspection of semiconductor packages to detect fine voids with high accuracy. However, obtaining high-quality CT images stably is difficult because of object misalignment. In this paper, we propose a method for improving the X-ray CT image quality by estimating the mechanical misalignment of each projection image. The estimation is conducted by using an iterative method based on the characteristic features obtained from the reconstructed image. In experiments, we verified the effectiveness of proposed method by using projection images with simulated misalignments added. The results indicated that the proposed method may be useful for improving the quality of CT imaging.

Content from these authors
© 2017 by the Institute of Electrical Engineers of Japan
Previous article Next article
feedback