2021 Volume 141 Issue 12 Pages 976-984
In this study, we propose a novel pulse-width modulation (PWM) method to reduces common-mode noise. The proposed method includes a 120-degree dormant two-phase modulated three-phase inverter that the comparative carrier of one of the two modulation phases. This configuration is easy to implement because it uses a triangular-wave carrier comparison. In an experiment using a three-phase inverter, the common-mode current was reduced by approximately 60%, and in particular, the carrier frequency component was reduced to approximately 1/10 that of the conventional sine-wave comparison PWM.
The transactions of the Institute of Electrical Engineers of Japan.C
The transactions of the Institute of Electrical Engineers of Japan.B
The transactions of the Institute of Electrical Engineers of Japan.A
The Journal of the Institute of Electrical Engineers of Japan