2021 Volume 141 Issue 8 Pages 591-597
This paper proposes an extended method of zero-voltage switching (ZVS) range for a dual active bridge (DAB) matrix converter with a discontinuous current mode (DCM). In the traditional DAB converter, ZVS cannot be achieved at a light load condition. The duty ratio calculation to achieve power factor correction and ZVS is explained using a circulating current. From the experimental results using a 5-kW prototype, the ZVS operation with zero transmission power is achieved by increasing the circulating current. In addition, the grid current distortion is lower than 5.0% at the rated power regardless of the DC voltage variation of plus or minus 20%.