2023 年 143 巻 12 号 p. 785-794
This paper discusses a compressor drive system for a room air conditioner. The system uses a single shunt current detection and a position sensor-less vector control technique. In addition, a new adaptive flux observer that considers the fluctuation in current detection timing is also proposed. The proposed observer improves the accuracy of speed estimation in a high-speed rotational condition. The room air conditioner, including this compressor drive system, has been mass-produced in our company.