2024 Volume 144 Issue 11 Pages 753-760
This study aims to improve the efficiency of an induction motor. The efficiency was measured under a load test using the inverter drive to verify the loss reduction effect when the winding changeover was applied. The stray load loss of series connection with a 184V synchronous 3 pulse could be reduced by 78% compared to the parallel connection with a 92V asynchronous pulse width modulation. Moreover, it was confirmed that the efficiency of the series connection is improved by approximately 4.4% compared to the parallel connection. Based on the above, it is confirmed that switching between series and parallel connections using a winding switcher can increase the efficiency of induction motors.
The transactions of the Institute of Electrical Engineers of Japan.C
The transactions of the Institute of Electrical Engineers of Japan.B
The transactions of the Institute of Electrical Engineers of Japan.A
The Journal of the Institute of Electrical Engineers of Japan