1995 Volume 115 Issue 8 Pages 1006-1014
Equivalent circuit parameters are obtained on 19 test motors, whose outputs are in 5.5KW to 6100 hp range of sizes, by which the calculated characteristics such as current, input and slip coincide quite closely with measured ones, and characteristic errors are obtained. Variation of the secondary equivalent circuit parameters with the secondary frequency f2 is obtained. It is shown that the secondary resistance r2 increases with f2 decreases in some motors. Effects of the shape of the rotor slot and magnetic saturation on the secondary circuit parameters are investigated. Effects of the no-load test voltage on the secondary equivalent circuit parameters, and characteristic errors are discussed.