IEEJ Transactions on Industry Applications
Online ISSN : 1348-8163
Print ISSN : 0913-6339
ISSN-L : 0913-6339
A Method of Speed Sensorless Direct Field Oriented Control based on Flux Observer for Current Source Inverter Drive Induction Machine
Nobuyuki KasaTomoyuki KarinoHiroshi Watanabe
Author information
JOURNALS FREE ACCESS

1996 Volume 116 Issue 1 Pages 56-64

Details
Abstract

Many sensorless vector control systems have been proposed to increase the reliability and to reduce costs of the systems. However the parameters of an induction machine are changed by the temperature, the estimated speed may be incorrect value. When a constant torque drive system is constructed by a sensorless system and a current source inverter (CSI), the accuracy of the estimated speed influenced directly the response of the torque.
In this paper, a direct field oriented control system is constructed by the flux observer which is low sensitivity to the rotor resistance variation and a proposed speed estimation scheme in a torque control system driven by a CSI. We compared experimental results by a voltage source inverter system and by the CSI system which is adopted our sensorless vector control scheme. At a lower speed condition, the system identifies the stator resistance, and we can estimate rotor speed correctly. Then the CSI system drives stably the induction machine without the speed sensor in a lower speed condition, and it can be applied to the constant torque drive systems.

Information related to the author
© The Institute of Electrical Engineers of Japan
Previous article Next article
feedback