2001 Volume 121 Issue 10 Pages 1024-1031
Novel approach for operation analysis of vector control synchronous machine has been described. To draw the vector diagram under adjustable speed operation, the concept of normalized voltage has been introduced. It is to divide the voltage value by angular frequency of the machine, then the voltage vectors, which contain angular frequency immanently, will not change their length under adjustable speed operation, and the vector diagram will keep its size unchanged for the whole speed range. Also, reactance drop locus and its accompanying yardstick circle for determining current phase angle, in corresponding to the variation of the given armature current vector, were deduced. Then, the operation of the machine for the whole adjustable speed range can be represented in single diagram. As the accompanying matters, the methods for calculating the operating characteristics of maximum torque control and 100% power factor control were shown.
The transactions of the Institute of Electrical Engineers of Japan.C
The transactions of the Institute of Electrical Engineers of Japan.B
The transactions of the Institute of Electrical Engineers of Japan.A
The Journal of the Institute of Electrical Engineers of Japan