Passive Cancellation of Input and Output Common-Mode Noise in Three-Phase PWM Inverter-Fed Motor Drive Systems
Shotaro TakahashiRyosuke Kanbayashi
Author information
JOURNAL FREE ACCESS Advance online publication

Article ID: 24009161

Details
Abstract

This article presents an input/output passive common-mode noise canceller to suppress common-mode (CM) currents on the input and output sides of a three-phase pulse-width-modulation inverter-fed motor drive system. Unlike conventional configurations where common-mode transformers (CMTs) are concentrated only on the input or output side of the inverter, the proposed method distributes CMTs on both sides. The proposed configuration enables the CM current flowing through the heat sink ground wire of the inverter to be suppressed effectively. Consequently, the proposed method improves the CM current attenuation characteristics of conventional methods. Experimental results demonstrate the effectiveness of the proposed method.

Content from these authors
© 2025 The Institute of Electrical Engineers of Japan
feedback