カソード内部加湿方式水素燃料固体高分子形燃料電池のガス供給形式による特性変化
狩野 昭雄田中 和久青木 努小上 泰司佐宗 秀寿阿部 聡針山 卓西川 尚男
著者情報
ジャーナル フリー

2006 年 126 巻 8 号 p. 821-826

詳細
抄録

With high hydrogen utilization operation, a minor imbalance in the distributed flow of the stack causes a shortage of hydrogen gas. In order to achieve high hydrogen utilization operation, we investigated the flow pattern for cells internally humidified at the cathode side. We fabricated both counter flow and co flow type cells for humidification of the cells inside the cathode and carried out electricity generation tests on single cells and cell stacks. Also we measured the distribution of relative humidity at the anode electrode for counter flow and co flow humidification of the cell inside the cathode. From these test results we concluded that the counter flow method is superior as a humidification cell inside a cathode when using the stack division method.