電気学会論文誌B(電力・エネルギー部門誌)
Online ISSN : 1348-8147
Print ISSN : 0385-4213
ISSN-L : 0385-4213
特集論文
500台規模太陽光発電システム集中連系時の単独運転検出機能のY法解析手法
柴田 秀一宮南 一也滝川 清杉原 裕征
著者情報
ジャーナル フリー

2007 年 127 巻 10 号 p. 1067-1072

詳細
抄録
Since the FY2003, the demonstration site Josai-no-mori including over 500 residences with PV system has been under construction at the Ota City, Gunma prefecture in Japan. It is important to clear the safety of islanding protection. However, it is very difficult to verify the islanding phenomena including many PV systems on the actual utility grid, where the people are leading life actually. Therefore, it becomes important to develop a technique employing simulation analysis for the safety evaluation.
Purpose of our study is to clear the details of dangerous islanding phenomena and the effects of various protection methods under clustered installation of over 500 PV systems within a partial area of utility grid. To solve these problems, a new analysis method has been developed, that is based on the CRIEPI's Power system Analysis Tools (CPAT) technology implemented by CRIEPI, so called “Y-method".
As a noteworthy result, it has been confirmed that the new simulation method has a capability to expand to the large-scale clustered installation model including 500 PV systems on utility grid. The validity of simulation analysis has been verified by comparing with preliminary indoor tests. In addition, it has been clarified that the combination of passive and active protection methods is very effective to avoid the islanding phenomena.
著者関連情報