電気学会論文誌B(電力・エネルギー部門誌)
Online ISSN : 1348-8147
Print ISSN : 0385-4213
ISSN-L : 0385-4213
論文
自力消弧室の吹付け角度と上流圧力分布の実験的検討
新海 健宇田川 恵佑鈴木 克巳
著者情報
ジャーナル フリー

2010 年 130 巻 9 号 p. 839-844

詳細
抄録
Pressure measurement with insulation tubes is successfully performed at the nozzle throat, in the upper flow path and in the thermal room for the two types of tandem-puffer (self-blast chamber) adopting different gas blast angle of nozzle. The pressure rise mechanism with auto-expansion effect of arc is discussed. The pressure rise in the upper flow path and the thermal chamber is driven by propagation of pressure wave from the arc to the thermal chamber. And several types of oscillation caused by rarefaction wave after the pressure wave and multi-reflection of the pressure wave are superposed on the pressure profile. Finally, an influence of the gas blast angle of the nozzle on cooling of stagnation point (thermal interruption capability) is explained based on the results of these measurement and 2-dimensional thermo-fluid analysis. A little larger gas blast angle of the nozzle leads to stronger gas flow to the stagnation point caused by a little larger resistance to the pressure wave and the gas flow.
著者関連情報
© 電気学会 2010
前の記事 次の記事
feedback