太陽光発電大量導入時の一機無限大母線系統の過渡安定度解析
坂本 尚也谷口 治人太田 豊中島 達人千貫 智幸
著者情報
ジャーナル フリー

2012 年 132 巻 1 号 p. 9-15

詳細
抄録
Large penetration of PV may affect transient stability when fault occurs on a transmission line. Classical model for a synchronous generator, a constant current source model for PV and a constant impedance model for load are applied to the one-machine-to-infinite-bus model. The critical clearing time is calculated by using equal area criterion and Y method simulation. As a result, a case with larger PV penetration has longer CCT than the case without PV penetration and this result does not depend on the reduction of synchronous generator capacity according to PV output.