電気学会論文誌B(電力・エネルギー部門誌)
Online ISSN : 1348-8147
Print ISSN : 0385-4213
ISSN-L : 0385-4213
特集論文
常時PMU計測値を用いた短絡電流推定手法とその実系統試験
Suresh Chand Verma中地 芳紀和澤 良彦小坂 葉子小林 武則小俣 和也高林 芳樹
著者情報
ジャーナル フリー

2013 年 133 巻 1 号 p. 37-44

詳細
抄録
This paper proposes estimation methods of short circuit current using phasor measurement unit (PMU) measurements (phasors). The methods follow the basic notion of representing the source side of a power system by an equivalent circuit with a voltage behind back impedance, and employ a set of voltage and current phasors measured at substations during the normal variation of loads in their estimation. In order to improve the estimation accuracy of the proposed methods, the concept of using the changes between the consecutive phasors is introduced. Furthermore, to make the methods applicable to the real world system, a reference phasor concept to remove the effects of system wide frequency variations and a filtering process to filter out the outlier phasors, are proposed and implemented. The validity and effectiveness of the proposed methods were checked and confirmed using experiments and field tests.