IEEJ Transactions on Power and Energy
Online ISSN : 1348-8147
Print ISSN : 0385-4213
ISSN-L : 0385-4213
Special Issue Paper
Experimental Validation of Factors Causing Flicker from Frequency Feedback Method with Step Injection of Reactive Power
Keisuke ShirasakiNaotaka OkadaKenichiro SanoHideki Iwatsuki
Author information
JOURNAL FREE ACCESS

2018 Volume 138 Issue 8 Pages 651-658

Details
Abstract

Flicker may be caused by “frequency feedback method with step injection of reactive power” installed in PCS which is generally used as grid-connected inverter in Japan. Therefore, in this paper, characteristics of the flicker were investigated by experiments with actual PCS in single phase circuit. Furthermore, effective means for suppressing the flicker was considered by taking the cause of occurrence of flicker into account. Moreover, it was clarified the differences among PCSs on flicker using multiple actual PCSs. In conclusion, gain of frequency feedback function should be reduced as one of effective means to avoid flicker.

Content from these authors
© 2018 by the Institute of Electrical Engineers of Japan
Previous article Next article
feedback
Top