電気学会論文誌B(電力・エネルギー部門誌)
Online ISSN : 1348-8147
Print ISSN : 0385-4213
ISSN-L : 0385-4213
分散型潮流監視・制御のための外部系統簡略化手法
田中 和幸
著者情報
ジャーナル フリー

1992 年 112 巻 12 号 p. 1129-1138

詳細
抄録
Load flow calculation on electric power systems is one of the most fundamental analysis in system operation and planning. There are many purposes to calculate load flow solutions, and the contingency evaluation is representative one.
In contingency evaluation, it is needed to repeat load flow calculation for tremendous patterns depending on branch or generation outages, then computing efforts are generally very heavy. So, various techniques have been proposed to reduce computing time especially by adopting equivalencing the external network. On the other hand, network equivalents techniques also become important nowadays from the viewpoint of necessity of decentralized monitor and control on bulk power systems.
This report describes newly developed method of load flow equivalents based on Ward equivalent for both direct (DC) solution and precise (AC) solution. Numerical results are also shown to clarify the accuracies and practicality of proposed method through the comparison to representative REI approach.
著者関連情報
© 電気学会
前の記事 次の記事
feedback
Top