電気学会論文誌B(電力・エネルギー部門誌)
Online ISSN : 1348-8147
Print ISSN : 0385-4213
ISSN-L : 0385-4213
HIGH ENTHALPY EXTRACTION EXPERIMENT WITH FUJI-1 CCMHD FACILITY
Effect of Channel Shape
Nobuhiro HaradaTetsuya SuekaneKazumi TsunodaSusumu Shioda
著者情報
ジャーナル フリー

1994 年 114 巻 9 号 p. 938-944

詳細
抄録

Power generation experiments have been performed for disk type MHD generators with different channel shape. The increase of enthalpy extraction ratio by enlargement of area ratio has been shown experimentally and the highest enthalpy extraction ratio of 18.0% has been achieved with the area ratio of 6.9. Experimental results have also shown that for the generator with large area ratio, wall static pressure in the MHD channel is kept lower than that for the generator with small area ratio. These results suggest that high Hall parameter can be obtained by enlargement of area ratio. Further we can see that we have to optimize area ratio of both the channel and the supersonic nozzle for optimum generator design. Finally, the effect of fluctuation of seed fraction on power output is discussed. It can be pointed out that more than 20% of enthalpy extraction can be realized when seeding system can be improved to eliminate fluctuation in seed fraction.

著者関連情報
© The Institute of Electrical Engineers of Japan
前の記事 次の記事
feedback
Top