電気学会論文誌B(電力・エネルギー部門誌)
Online ISSN : 1348-8147
Print ISSN : 0385-4213
ISSN-L : 0385-4213
大容量ガス絶縁変圧器の関発
高橋 英二田中 晃司戸田 克敏池田 正己寺西 常治稲葉 正明毛受 新一
著者情報
ジャーナル フリー

1995 年 115 巻 4 号 p. 346-352

詳細
抄録
Because the gas forced cooling type gas-insulated transformer was considered to be available up to approximately 60MVA, several types of liquid cooling large-capacity gas-insulated transformer have been developed. But liquid cooling type has a disadvantage of complex structure for liquid cooling.
In this reason, authors have been studying to develop the simple design of gas forced cooling large-capacity gas-insulated transformer. This paper deals with reseach and development of cooling and insulation technology of large-capacity gas-insulated transformer. Cooling characteristics of high pressure SF6 gas have been studied for cooling design. Turn-to-turn and section-to-section insulation of gas-insulated transformer winding have been studied for insulation design. Furthermore, development of 275kV 300MVA gas-insulated transformer is described.
著者関連情報
© 電気学会
前の記事 次の記事
feedback