電気学会論文誌B(電力・エネルギー部門誌)
Online ISSN : 1348-8147
Print ISSN : 0385-4213
ISSN-L : 0385-4213
稼働率と修理交換率に基づく電力設備の適正点検間隔決定法
片渕 達郎中村 政俊鈴木 禎宏籏崎 裕章
著者情報
ジャーナル フリー

2002 年 122 巻 8 号 p. 891-899

詳細
抄録
In this paper, a reasonable method has been proposed to determine the maintenance schedule of turbine in thermal power stations. Due to a fact that many failure data do not exist, we paid attention to the maintenance replacement rate, and the dimensional reduction method was used. Proper maintenance interval based on future operation rate was decided by the relationship between operation rate and maintenance interval. The results of analysis can reduce the maintenance cost, meanwhile keeping current reliability. The proposed method will be adopted by Kyushu Electric Power Co. from April in 2002 to determine the maintenance schedule of turbine in thermal power stations. Moreover, it can be also applied for any other systems.
著者関連情報
© 電気学会
前の記事 次の記事
feedback