IEEJ Transactions on Sensors and Micromachines
Online ISSN : 1347-5525
Print ISSN : 1341-8939
ISSN-L : 1341-8939
Paper
Capacitive Micromachined Ultrasonic Transducers Using Anodically Bondable Ceramic Wafer with Through-Wafer Via
Misaki HiroshimaTadao MatsunagaTakashi MinetaYoichi Haga
Author information
JOURNAL FREE ACCESS

2014 Volume 134 Issue 10 Pages 333-337

Details
Abstract
This paper describes the design and experimental results of CMUTs (Capacitive Micromachined Ultrasonic Transducers) using an anodically bondable LTCC (Low Temperature Co-fired Ceramics) wafer. Electrical connection of the CMUTs top electrode and the LTCC via were successfully performed at a time of anodic bonding by forming Au bump on the electrode. The vibration characteristics of the membrane were measured by a laser Doppler vibrometer both in the atmosphere and in the water. Ultrasonic pressure signal of CMUTs arrays was measured using hydrophone.
Content from these authors
© 2014 by the Institute of Electrical Engineers of Japan
Previous article Next article
feedback