IEEJ Transactions on Sensors and Micromachines
Online ISSN : 1347-5525
Print ISSN : 1341-8939
ISSN-L : 1341-8939
Paper
Real-time Skin Lactic Acid Monitoring System for Assessment of Training Intensity
Keigo EnomotoRyosuke ShimizuHiroyuki Kudo
Author information
JOURNAL FREE ACCESS

2017 Volume 137 Issue 12 Pages 450-454

Details
Abstract

A microfluidic system using electrochemical biosensor for continuous lactic acid (LA) monitoring at the skin's surface was fabricated and tested. The system consists of a micro flow-cell for sampling LA at the skin's surface and a microfluidic LA biosensor based on a redox reaction of osmium wired horseradish peroxidase (Os-HRP). Our system measures excreted LA by dissolving whole secretion in phosphate buffered saline (PBS), which was supplied into the micro channel as carrier flow. The measurement system was utilized in the real-time monitoring of LA secretion during stationary bike exercises. Exercise intensities were regulated by heartrates (HR) and the sampling device was attached on the right upper arm of the volunteer. During the exercise, PBS was circulated into the measurement system. As a result, change of LA levels correlated with the volunteer's physiological status was confirmed. Secretion of LA was estimated to be 4.50 µg/cm2/min when the intensity of exercise was high (HR: 160 bpm) and the signal decreased to the initial level after the exercise. This indicates that our system is suitable for not only the assessment of exercise intensity, but also useful in evaluation of metabolic activity.

Content from these authors
© 2017 by the Institute of Electrical Engineers of Japan
Previous article Next article
feedback