IEEJ Transactions on Sensors and Micromachines
Online ISSN : 1347-5525
Print ISSN : 1341-8939
ISSN-L : 1341-8939
Reduction of Microvalve Leakage based on Precise Measurement of Flow Conductance
Motohisa HiranoKeiichi YanagisawaHiroki KuwanoSatoko Nakano
Author information
JOURNAL FREE ACCESS

1997 Volume 117 Issue 12 Pages 622-626

Details
Abstract
This paper reports a reduction of microvalve leakage according to precise measurements of the leak and flow rates. The tight contact between a valve cap and seat, which is obtained by nanometer-scale flat surfaces and by self-alignment of a cap and seat-bore, makes the leakage from a microvalve ultra-low. The leak and flow rates are determined by precisely measuring pressure changes when introducing helium gas into a flow line. We have, consequently, attained a leak rate as low as 5.8×10-10Pa⋅m3/s and a flow rate ranging from 5.8×10-10 to 3.2×10-4Pa⋅m3/s.