International Heart Journal
Online ISSN : 1349-3299
Print ISSN : 1349-2365
ISSN-L : 1349-2365
Case Reports
A Steam Pop Detected by Intracardiac Echocardiography During Catheter Ablation of the Left Ventricular Papillary Muscle
Akinori SatoNobue YagiharaYuki HasegawaSou OtukiKenichi IijimaDaisuke IzumiTohru Minamino
著者情報
ジャーナル フリー

2019 年 60 巻 1 号 p. 199-203

詳細
抄録

A 60-year-old female with premature ventricular contractions (PVCs) originating from the bottom of the posteromedial papillary muscle of the left ventricle underwent radiofrequency catheter ablation (RFCA) using an irrigated-tip catheter. During ablation of the PVCs, a loud steam pop was observed. Intracardiac echocardiography (ICE) revealed a growing, hyperechogenic intramyocardial microbubble formation around the catheter tip. The formation disappeared slowly and completely, leaving an endocardial laceration without pericardial effusion. ICE imaging is valuable during a difficult RFCA procedure, because ICE reveals the exact anatomical position of the catheter and thus allows rapid evaluation of the occurrence of steam popping and any possible subsequent complication.

著者関連情報
© 2019 by the International Heart Journal Association
前の記事 次の記事
feedback