Japanese Heart Journal
Online ISSN : 1348-673X
Print ISSN : 0021-4868
ISSN-L : 0021-4868
Optimal Size of Outflow Patch in Total Correction of Tetralogy of Fallot
Akira FURUSEAkira MIZUNOGoki SHINDOTakaji YAMAGUCHIMasahiro SAIGUSA
著者情報
ジャーナル フリー

1977 年 18 巻 5 号 p. 629-637

詳細
抄録

Hemodynamic and angiocardiographic studies were performed in postoperative patients with tetralogy of Fallot. Pressure gradient between the right ventricle and pulmonary artery was correlated with the narrowest area in the pulmonary arterial pathway. Regurgitant fraction was also correlated with regurgitant area which was determined by preoperative area of the pulmonic annulus and width of the outflow patch. Follow-up study of postoperative patients with tetralogy indicated that those with pressure gradient less than 20mmHg and regurgitant fraction less than 15% could be considered ideally corrected. A table was constructed for determining the most appropriate width of the outflow patch for the ideal correction.

著者関連情報
© by International Heart Journal Association
前の記事 次の記事
feedback