International Journal of Fluid Machinery and Systems
Online ISSN : 1882-9554
ISSN-L : 1882-9554
Original papers
Effect of Vortex Design on a Half-Ducted Axial Flow Fan (In the case of forced vortex design)
Atsushi KajiYoichi KinoueNorimasa ShiomiToshiaki Setoguchi
著者情報
ジャーナル フリー

2018 年 11 巻 1 号 p. 46-54

詳細
抄録

An improvement of the half-ducted axial flow fan design by applying the forced vortex design to the rotor blade was conducted by CFD. The quasi three-dimensional flow theory was applied for the half-ducted fan design, and the meridional flow was calculated by the method of streamline curvature. When the radial balance equations from hub to tip was solved, the vortex design was changed from the constant-whirl-velocity design to the forced vortex design in reference to our previous experimental results of the half-ducted fan's internal flow. The analysis of the three-dimensional internal flow fields of the half-ducted fan designed by adopting the forced vortex design was conducted. As a result of CFD, the efficiency η of the fan was about 1-3 % larger at the flow rate coefficient φ of 0.158-0.343 than the constant-whirl-velocity design.

著者関連情報

この記事は最新の被引用情報を取得できません。

© 2018 Turbomachinery Society of Japan, Korean Fluid Machinery Association, Chinese Society of Engineering Thermophysics, IAHR
前の記事 次の記事
feedback